Home

Protection Methods for Potentially Explosive Gas/Vapour Atmospheres

Protection Method North America Class I Europe (CENELEC)
International (IEC)
Div. Standard Zone Standard Zone Standard
Canada (CSA) US Canada (CSA) US European Norm (EN) International (IEC)
Intrinsic Safety - ia (2 faults) 1 C22.2 No. 157 FM3610/UL913 0 E60079-11 ISA 12.02.01/UL2279 0 50020 60079-11
Intrinsic Safety - ib (1 fault) 1 E60079-11 ISA 12.02.01/UL2279 1 50020 60079-11
Explosionproof Flameproof - d 1 C22.2 No. 30 FM3615/UL1203 1 E60079-1 ISA S12.22.01/UL2279 1 50018 60079-1
Purged Pressurized - p 1/2 CSA TIL 13A/NFPA 496 NFPA 496 1/2 E60079-2 1 50016 60079-2
Increased Safety - e 1 E79-7 ANSI/ISA S12.16.01/UL2279 1 50019 60079-7
Encapsulation - m 1 E79-18 ISA S12.23.01/UL2279 1 50028 60079-18
Oil immersion - o 1 E79-6 ANSI/ISA S12.26.01/UL2279 1 50015 60079-6
Powder filled - q 1 E60079-5 ANSI/ISA S12.25.01/UL2279 1 50017 60079-5
Non-incendive/non-sparking 2 C22.2 No. 213 FM3611/UL1604
Protection - n 2 E60079-15 UL2279 2 50021 60079-15
Special requirements (2 protection methods) 0 50284

Protection Methods for Combustible/Ignitable Dust Atmospheres

Protection Method North America Class II, III Europe (CENELEC)
International (IEC)
Div. Standard Zone Standard
Canada (CSA) US European Norm (EN) International (IEC)
Intrinsic Safety - ia 1 C22.2 No. 157 FM3610/UL913
Dust ignition protection 1 C22.2 No. 25 or E61241-1-1 UL 1203 20 / 21 / 22 EN50281-1-1 61241-1-1
Purged 1/2 NFPA 496 61241-4
Dust tight 2 C22.2 No. 25 or E61241-1-1 FM3611/UL1604
Non-incendive 2 FM3611/UL1604

Hazardous Locations Equipment Marking

Markings for North America Markings for Europe
Option A: (ZoneSystem) ATEX Directive (94/9/EC) on
Ex ia IIC T4 (Canada)
Class I Zone 0 AEx ia IIC T4 (U.S.)
Potentially Explosive Atmospheres
Flammable gas or vapour Area classification Conformity to U.S. requirements Explosion protected Protection method - (intrinsic safety) Gas group (acetylene & hydrogen) Temperature code CE marking symbol ID No. of Notified Body of the QA system EU Explosive Atmospheres symbol Surface (non-mining) equipment Equipment category Type of flammable substance
Class I Zone 0 A Ex ia IIC T4 ... II 1 G
Option B: (DivisionSystem) CENELEC (European) Directive (76/117/EEC)
Flammable gas or vapour Area Classification Gas group -
A: acetylene
B: hydrogen
C: ethylene
D: propane
Temperature Code Conformity to CENELEC standard Explosion protected Protection method - (intrinsic safety) Gas group (acetylene & hydrogen) Temperature Class EU marking for explosion protection (optional)
Class I Division 1 Groups A, B, C, D T4 EEx EEx ia IIC T4

ATEX Directive 94/9/EC

Equipment Group Equipment Category and Level of Protection Presence of Explosive Atmosphere Flammable Substances Correlation with Hazardous Areas
I - Mines M1 - very high level of protection Presence Methane, Dust
M2 - high level of protection Risk of Presence
II - Surface 1 - very high level of protection Continuous Presence G-Gas, Vapours Mist; D-Dust Zone 0 (Gas etc.) Zone 20 (Dust)
2 - high level of protection Likely to Occur Zone 1 (Gas etc.) Zone 21 (Dust)
3 - normal level of protection Unlikely to Occur Zone 2 (Gas etc.) Zone 22 (Dust)

Ingress Protection (IP) Codes

First NUMERAL Protection Against Solid Bodies SECOND NUMERAL Protection Against Water
0 No Protection 0 No Protection
1 Objects Greater Than 50 mm 1 Vertically Dripping
2 Objects Greater Than 12.5 mm 2 Angled Dripping (15° tilted)
3 Objects Greater Than 2.5 mm 3 Spraying
4 Objects Greater Than 1.0 mm 4 Splashing
5 Dust-Protected 5 Jetting
6 Dust-Tight 6 Powerful Jetting
7 Temporary Immersion
6 Continuous Immersion

Temperature Codes & Classes

Maximum Surface Temperature (°C) US (NEC) Canada (CEC) US (NEC) Canada (CEC) IEC, CENELEC
450 T1 T1
300 T2 T2
280 T2A
260 T2B
230 T2C
215 T2D
200 T3 T3
180 T3A
165 T3B
160 T3C
135 T4 T4
120 T4A
100 T5 T5
85 T6 T6

Apparatus Grouping

Typical Gas/Dust/Fibres/Flyings US (NEC) Canada (CEC) US (NEC) Canada (CEC) IEC, CENELEC
Acetylene Class I, Group A Group IIC
Hydrogen Class I, Group B
Ethylene Class I, Group C Group IIB
Propane Class I, Group D Group IIA
Methane Gaseous Mines* Group I*
Magnesium Class II, Group E IEC, CENELEC do not subdivide by material types
Coal Class II, Group F
Grain Class II, Group G
Cotton Class III
*not within scope of NEC or CEC
Class I - gas/vapour/mist, Class II - dust, Class III - fibres, flyings

Area Classifications Division vs. Zone

Type of Area NEC and CEC (North America) ATEX and IEC
Continuous Hazard Division 1 or Zone 0 Zone 0
Intermittent Hazard Division 1 or Zone 1 Zone 1
Hazard Under Abnormal Conditions Division 2 or Zone 2 Zone 2

NEMA/CSA/UL Enclosure Types

Type Application Abbreviated Definition*
1 Indoor General Purpose
2 Indoor Protection against angled dripping water
3, 3R, 3S Indoor/Outdoor Protection against rain, snow
4, 4X Indoor/Outdoor Protection against rain, snow, hose directed water
5 Indoor/Outdoor Protection against angled dripping water, dust, fibres, flyings
6 Indoor/Outdoor Protection against temporary submersion
6P Indoor/Outdoor Protection against prolonged submersion
12, 12K Indoor Protection against circulating dust, fibres, flyings
13 Indoor Protection against circulating dust, fibres, flyings, seepage
*refer to the enclosure standard for detailed definitions - CSA C22.2 No. 94, UL 50

© of Graham Sensor Technologies Inc